Key points for safe use of UPS power supply system

Key points for safe use of UPS power supply system



The following summarizes the use of UPS UPS UPS system precautions, correct operation can extend the service life of the system and improve work efficiency.


1. There are many high voltage energy storage devices in the main unit of UPS power supply. Please do not open the case for inspection without authorization. The operator must know the basic knowledge of electrician and read the operation manual.


2. Please do not dismantle all kinds of connecting cables without authorization. Contact the supplier or after-sales technical service personnel for operation.


3. Do not move or dismantle UPS UPS system at will, do not crack and vibrate strongly, and keep good ventilation.


4. UPS UPS UPS system is connected with battery, even if the AC mains power supply is not connected, there may still be voltage at its output end. Keep this in mind.


5. When the UPS UPS system needs to be moved or rewired, it must be ensured that the UPS is completely shut down and the air switch of the mains power input and battery input is disconnected. Otherwise, the output may still have electricity, which may cause electric shock.


6. In order to ensure the personal safety of users, UPS products must have good grounding protection.


7. Please keep the air inlet and outlet unobstructed. The poor ventilation of the air inlet and exhaust port will lead to the temperature rise in the UPS UPS UPS system, shorten the service life of the components in the machine, thus affecting the service life of the whole machine.


8. Liquids or other foreign objects are not allowed to enter the UPS power box.


9. In case of fire around UPS system, please use dry powder fire extinguisher. If liquid fire extinguisher is used, there will be electric shock hazard.


10. The service life of UPS battery decreases with the increase of ambient temperature. Regular battery replacement can ensure that UPS UPS UPS system works normally and can maintain sufficient power supply backup time.


11. If it is not used for a long time, the ups must be stored in a dry environment.


12. When UPS system is out of service for a long time, it is recommended to connect UPS system every 3 months for more than 12 hours to charge the battery, so as to avoid battery damage due to long-term use.


13. Do not turn on the ups battery. The electrolyte will cause damage to the skin and eyes. If the electrolyte is accidentally contacted, clean it with plenty of water and go to the hospital for examination.


14. When the UPS UPS system is charged, do not use a wet towel to erase the dirt.


15. UPS batteries must be replaced by professional technicians, and the replaced batteries must be sent to a special recycling organization for treatment.

CONTACT US

Contact: APC UPS Power Supply (China) Co., Ltd.

Phone: 13001085780

Tel: 400-881-0312

Email: 197652078@qq.com

Add: Time Network Building, No. 19 Haidian South Road, Haidian District, Beijing

Scan the qr codeClose
the qr code