Welcome: APCUPS Power Supply-APCUPS Power Supply (China) Co., Ltd. [Official Website]
Language: Chinese ∷  English

News

Maintenance contents of APC Schneider UPS power supply equipment

Maintenance contents of APC Schneider UPS power supply equipment



With the change of the times, information equipment is particularly strict on the grid environment. APC Schneider UPS power supply, as an important equipment to improve power grid pollution, also ushered in a broader market demand. For the users who have used APC Schneider UPS power supply, how to maintain the APC Schneider UPS power supply to increase its service life and play the most important role is the primary condition.


What is the maintenance of UPS power supply equipment?


1. Site maintenance


When installing and using APC Schneider UPS power supply, the temperature of installation and use environment should be 0 ~ 40 ℃, the relative humidity is 30% ~ 90%, the temperature is lower than 0 ℃ or it is affected by damp, the insulation performance of UPS power supply will decline, which is easy to cause short circuit; at the same time, it may also cause corrosion and rust of connectors, electrical connecting screws, component pins, hoes, solder joints, etc. of UPS power supply and other equipment.


If the altitude is more than 1000m, it should be reduced by 10% every 1000m.


In addition, APC Schneider UPS's antimagnetic ability is not very good. Therefore, the strong magnetic objects should not be placed on the ups, or APC Schneider ups will not work properly or damage the machine.


2. Battery maintenance


The battery is the APC Schneider UPS power supply as a device to store electric energy, the size of the capacity determines the maintenance discharge time.


(1) Maintain appropriate ambient temperature


Considering all aspects, APC Schneider UPS power supply generally uses maintenance free lead-acid battery, and its service life is generally about 5 years. The ambient temperature of the battery is between 20 ℃ and 25 ℃. Once the temperature exceeds 25 ℃, the battery life will be reduced by half every 10 ℃.


(2) The battery is charged and discharged regularly


In the service environment where there is little power failure, the battery will be in the state of floating charge for a long time, which will reduce the activity of chemical energy and electric energy conversion, accelerate aging and shorten the service life. Therefore, the battery should be fully discharged every 2-3 months, and the discharge time can be determined according to the capacity and load of the battery. After one full load discharge, recharge for more than 8 hours according to regulations.

CONTACT US

Contact: APC UPS Power Supply (China) Co., Ltd.

Phone: 13001085780

Tel: 400-881-0312

Email: 197652078@qq.com

Add: Time Network Building, No. 19 Haidian South Road, Haidian District, Beijing

Scan the qr codeClose
the qr code